The dew point is the temperature the air needs to be cooled to (at constant pressure) in order to produce a relative humidity of 100%. [1] This temperature depends on the pressure and water content of the air.
In hot summer weather, a rise in relative humidity increases the apparent temperature to humans (and other animals) by hindering the evaporation of perspiration from the skin. For example, according to the heat index, a relative humidity of 75% at air temperature of 80.0 °F (26.7 °C) would feel like 83.6 ± 1.3 °F (28.7 ± 0.7 °C). [13] [14]
The heat index (HI) is an index that combines air temperature and relative humidity, in shaded areas, to posit a human-perceived equivalent temperature, as how hot it would feel if the humidity were some other value in the shade. For example, when the temperature is 32 °C (90 °F) with 70% relative humidity, the heat index is 41 °C (106 °F ...
The saturation vapor pressure of water at any given temperature is the vapor pressure when relative humidity is 100%. One formula is Tetens' equation from [15] used to find the saturation vapor pressure is: = (()) where:
Schematic of the LCL in relation to the temperature (T) and dew point and their altitude (Z); the moist adiabatic temperature curve above the LCL is also sketched for reference The lifting condensation level or lifted condensation level ( LCL ) is the height at which the relative humidity (RH) of an air parcel will reach 100% with respect to ...
When the two tendencies are in balance— and the air and food are stable—the air's relative humidity (expressed as a fraction instead of as a percentage) is taken to be the water activity, a w. Thus, water activity is the thermodynamic activity of water as solvent and the relative humidity of the surrounding air at equilibrium.
The wet-bulb temperature is the lowest temperature that may be achieved by evaporative cooling of a water-wetted, ventilated surface.. By contrast, the dew point is the temperature to which the ambient air must be cooled to reach 100% relative humidity assuming there is no further evaporation into the air; it is the temperature where condensation (dew) and clouds would form.
To compute the VPD, [2] we need the ambient (greenhouse) air temperature, the relative humidity and, if possible, the canopy air temperature. We must then compute the saturation pressure. Saturation pressure can be looked up in a psychrometric chart or derived from the Arrhenius equation; a way to compute it directly from temperature is