The R-value is the building industry term [3] for thermal resistance "per unit area." [4] It is sometimes denoted RSI-value if the SI units are used. [5] An R-value can be given for a material (e.g., for polyethylene foam), or for an assembly of materials (e.g., a wall or a window). In the case of materials, it is often expressed in terms of R ...
All thermal insulation requirements in ASHRAE 90.1 are divided by the climate zone, it means that the amount of insulation needed for a building is determined by which climate zone the building locates. The thermal insulation requirements are shown as R-value and continuous insulation R-value as the second index. [14]
Closed-cell foams are superior insulators. While open-cell foams typically have R-values of 3 to 4 per inch (RSI-0.53 to RSI-0.70 per inch), closed-cell foams can attain R-values of 5 to 8 per inch (RSI-0.88 to RSI-1.41 per inch). This is important if space is limited, because it allows a thinner layer of insulation to be used.
Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
The first expanded polystyrene ICF Wall forms were developed in the late 1960s with the expiration of the original patent and the advent of modern foam plastics by BASF. [citation needed] Canadian contractor Werner Gregori filed the first patent for a foam concrete form in 1966 with a block "measuring 16 inches high by 48 inches long with a tongue-and-groove interlock, metal ties, and a waffle ...
At a time when most Canadian houses had 4-inch-thick (100 mm) walls with an insulation R-value of r-8, the Saskatchewan Conservation House had 12-inch-thick (300 mm) walls with r-40 insulation and a roof with r-60 insulation, [15] increasing the house's insulation to approximately six times compared to the standard.
Thermal insulance (R-value) is a measure of a material's resistance to the heat current. It quantifies how effectively a material can resist the transfer of heat through conduction, convection, and radiation.
Passive house buildings employ superinsulation to significantly reduce the heat transfer through the walls, roof and floor compared to conventional buildings. [60] A wide range of thermal insulation materials can be used to provide the required high R-values (low U-values, typically in the 0.10 to 0.15 W/(m 2 ·K) range).