When.com Web Search

  1. Ads

    related to: gas regulator distance from generator to power adapter

Search results

  1. Results From The WOW.Com Content Network
  2. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    All vehicular motors that run on compressed gas as a fuel (internal combustion engine or fuel cell electric power train) require a pressure regulator to reduce the stored gas (CNG or Hydrogen) pressure from 700, 500, 350 or 200 bar (or 70, 50, 35 and 20 MPa) to operating pressure. [citation needed])

  3. Switched-mode power supply - Wikipedia

    en.wikipedia.org/wiki/Switched-mode_power_supply

    Stand-alone switched-mode power supply An adjustable switched-mode power supply for laboratory use. A switched-mode power supply (SMPS), also called switching-mode power supply, switch-mode power supply, switched power supply, or simply switcher, is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently.

  4. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are synchronized.

  5. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  6. Power supply - Wikipedia

    en.wikipedia.org/wiki/Power_supply

    An external power supply, AC adapter or power brick, is a power supply located in the load's AC power cord that plugs into a wall outlet; a wall wart is an external supply integrated with the outlet plug itself. These are popular in consumer electronics because of their safety; the hazardous 120 or 240 volt main current is transformed down to a ...

  7. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.