When.com Web Search

  1. Ads

    related to: daily calibration of ph meter

Search results

  1. Results From The WOW.Com Content Network
  2. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    Beckman Model M pH Meter, 1937 [1] Beckman model 72 pH meter, 1960 781 pH/Ion Meter pH meter by Metrohm. A pH meter is a scientific instrument that measures the hydrogen-ion activity in water-based solutions, indicating its acidity or alkalinity expressed as pH. [2]

  3. Buffer solution - Wikipedia

    en.wikipedia.org/wiki/Buffer_solution

    A buffer solution is a solution where the pH does not change significantly on dilution or if an acid or base is added at constant temperature. [1] Its pH changes very little when a small amount of strong acid or base is added to it. Buffer solutions are used as a means of keeping pH at a nearly constant value in a wide variety of chemical ...

  4. pH - Wikipedia

    en.wikipedia.org/wiki/PH

    Two or more buffer solutions are used in order to accommodate the fact that the "slope" may differ slightly from ideal. To calibrate the electrode, it is first immersed in a standard solution, and the reading on a pH meter is adjusted to be equal to the standard buffer's value. The reading from a second standard buffer solution is then adjusted ...

  5. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    However, evaluation of daily performance must be documented to ensure continual production of valid data. A check should first be done to ensure that the data should be seen is precise and accurate. Next, systematic daily checks such as analysing blanks, calibration standards, quality control check samples, and references must be performed to ...

  6. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  7. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.