Minimum and maximum room ceiling heights, exit sizes and location; Qualification of individuals or corporations doing the work; For high structures, anti-collision markers for the benefit of aircraft; Building codes are generally separate from zoning ordinances, but exterior restrictions (such as setbacks) may fall into either category.
Interior loadbearing walls are framed in the same way as exterior walls. Studs are usually 1 + 1 ⁄ 2 in × 3 + 1 ⁄ 2 in (38 mm × 89 mm) lumber spaced at 16 in (410 mm) on center. This spacing may be changed to 12 or 24 in (300 or 610 mm) depending on the loads supported and the type and thickness of the wall finish used. [12]
Historically, multiple approaches were suggested to address the reflection of the structure in the appearance of the architectural form. In the 19th-century Germany, Karl Friedrich Schinkel suggested that the structural elements shall remain visible in the forms to create a satisfying feeling of strength and security, [3] while Karl Bötticher as part of his "tectonics" suggested splitting the ...
Exterior roof panels are usually a single continuous length from eave to ridge line for gable style buildings or from low eave to high eave on single slope or shed style buildings. Many manufacturers provide minimum 24 gauge (nominal: 0.0239 inch; 0.61 mm) thick sheet steel in self-framing roof designs.
A typical timber shear wall consists of braced panels in the wall line, constructed using structural plywood sheathing, specific nailing at the edges, and supporting framing. A shear wall is an element of a structurally engineered system that is designed to resist in- plane lateral forces, typically wind and seismic loads.
A curtain wall is an exterior covering of a building in which the outer walls are non-structural, instead serving to protect the interior of the building from the elements. Because the curtain wall façade carries no structural load beyond its own dead load weight, it can be made of lightweight materials.
Hong Kong law Chapter 123F, Building (Planning) Regulations, Regulation 23 sect 3 sub-paragraph (a) defined that: Subject to sub-paragraph (b), for the purposes of regulations 19, 20, 21 and 22, the gross floor area of a building shall be the area contained within the external walls of the building measured at each floor level (including any floor below the level of the ground), together with ...
A load-bearing wall or bearing wall is a wall that is an active structural element of a building — that is, it bears the weight of the elements above said wall, resting upon it by conducting its weight to a foundation structure. [1] The materials most often used to construct load-bearing walls in large buildings are concrete, block, or brick.