When.com Web Search

  1. Ads

    related to: sprinkler valve not closing completely

Search results

  1. Results From The WOW.Com Content Network
  2. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced to atmospheric pressure or below, the poppet valve drops and allows air to enter the system, breaking the siphon. [1]

  3. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity. High pipeline pressure rating (does not reduce the effect but protects against damage).

  4. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  5. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    It is commonly used on lawn irrigation, fire sprinkler [2] and combi-boiler systems. [3] If the hazard is higher, even a relatively low hazard such as using antifreeze in the fire sprinkler system, then a more reliable check valve such as a reduced pressure zone device may be mandated.

  6. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Regulations for these check valves specify the design capabilities of the valve used, according to the hazard. Category 2 contamination may be prevented by a single check valve, but category 3 requires a double check valve (these are manufactured as a convenient single unit, or even integrated into tap (faucet) fittings). Category 5 requires an ...

  7. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Fire sprinkler systems are generally designed as a life saving system, but are not necessarily designed to protect the building. Of buildings completely protected by fire sprinkler systems, if a fire did initiate, it was controlled by the fire sprinklers alone in 96% of these cases. [2]