  1. Results From The WOW.Com Content Network
  2. Register (air and heating) - Wikipedia

    en.wikipedia.org/wiki/Register_(air_and_heating)

    A register's damper provides a critical function. Primarily, the damper allows the amount of hot or cool air entering a room to be controlled, providing for more accurate control over room temperature. [7] Dampers also allow air to be shut off in unused rooms, improving the efficiency of the HVAC system.

  3. Smoke damper - Wikipedia

    en.wikipedia.org/wiki/Smoke_damper

    Smoke dampers close by an electric or pneumatic actuator, or a spring actuator, and can be either manually reset or driven open on a reset signal to the electric or pneumatic actuator. Combination fire/smoke dampers are also available if a smoke barrier is desired at the same location as a fire barrier.

  4. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  5. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...

  6. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    smoke damper A damper or adjustable louver designed to augment the ventilation of a space during a fire. split system A split system is the combination of an outdoor unit and an indoor unit. This is the most common type of system. superheat The number of degrees a vapor is above its boiling point at a specific pressure. subcooling

  7. Citicorp Center engineering crisis - Wikipedia

    en.wikipedia.org/wiki/Citicorp_Center...

    [21] [26] With the tuned mass damper active, LeMessurier estimated that a wind capable of toppling the building had a one in fifty-five chance of happening any year. [27] [21] But if the tuned mass damper could not function due to a power outage, a wind strong enough to cause the building's collapse had one chance in sixteen of happening any ...