When.com Web Search

  1. Ad

    related to: main parts of centrifugal pump control circuit open

Search results

  1. Results From The WOW.Com Content Network
  2. Centrifugal pump - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_pump

    Another type of self-priming pump is a centrifugal pump with two casing chambers and an open impeller. This design is not only used for its self-priming capabilities but also for its degassing effects when pumping two-phase mixtures (air/gas and liquid) for a short time in process engineering or when handling polluted fluids, for example, when ...

  3. Impeller - Wikipedia

    en.wikipedia.org/wiki/Impeller

    Several different types of pump impellers Flexible impeller of cooling system pump of an outboard engine (1 euro cent coin for comparison, diameter 16.25 mm). An impeller is a rotating component of a centrifugal pump that accelerates fluid outward from the center of rotation, thus transferring energy from the motor that drives the pump to the fluid being pumped.

  4. Centrifugal pump selection and characteristics - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_pump_selection...

    While centrifugal pumps impart momentum to the fluid by motion of blades, positive displacement pumps transfer fluid by variation in the size of the pump’s chamber. Centrifugal pumps can be of rotor or propeller types, whereas positive displacement pumps may be gear-based, piston-based, diaphragm-based, etc. As a general rule, centrifugal ...

  5. Chopper pumps - Wikipedia

    en.wikipedia.org/wiki/Chopper_pumps

    A chopper pump is a centrifugal pump which is equipped with a cutting system to facilitate chopping or maceration of solids that are present in the pumped liquid. The main advantage of this type of pump is that it prevents clogging of the pump itself and of the adjacent piping, as all the solids and stringy materials are macerated by the ...

  6. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  7. Control system - Wikipedia

    en.wikipedia.org/wiki/Control_system

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  8. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  9. Axial piston pump - Wikipedia

    en.wikipedia.org/wiki/Axial_piston_pump

    A direct displacement control pump contains linkages and springs and in some cases magnets rather than a shaft to a motor located outside of the pump (thereby reducing the number of moving parts), keeping parts protected and lubricated and reducing the resistance against the flow of liquid. servo control pump. Pressure. In a typical pressure ...