When.com Web Search

  1. Ad

    related to: sq mm to awg converter calculator formula

Search results

  1. Results From The WOW.Com Content Network
  2. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    The conversion factor from square mils to circular mils is therefore 4/ π cmil per square mil: 4 π c m i l m i l 2 . {\displaystyle {\rm {{\frac {4}{\pi }}{\frac {cmil}{mil^{2}}}.}}} The formula for the area of an arbitrary circle in circular mils can be derived by applying this conversion factor to the standard formula for the area of a ...

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    However, AWG is dissimilar to IEC 60228, the metric wire-size standard used in most parts of the world, based directly on the wire cross-section area (in square millimetres, mm 2). The AWG tables are for a single, solid and round conductor. The AWG of a stranded wire is determined by the cross-sectional area of the equivalent solid conductor.

  4. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    IEC 60228, the metric wire-size standard used in most parts of the world. Circular mil, Electrical industry standard for wires larger than 4/0. American Wire Gauge (AWG), used primarily in the US and Canada; Stubs Iron Wire Gauge; Jewelry wire gauge; Body jewelry sizes; Electrical wiring; Number 8 wire, a term used in the New Zealand vernacular

  5. Square mil - Wikipedia

    en.wikipedia.org/wiki/Square_mil

    A square mil is a unit of area, equal to the area of a square with sides of length one mil. A mil is one thousandth of an international inch . This unit of area is usually used in specifying the area of the cross section of a wire or cable.

  6. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. The first attempt to adopt a geometrical system was made by Messrs Brown & Sharpe in 1855.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  8. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    For wire sizes smaller than AWG No. 2 (33.6 mm 2, 0.0521 sq in), this term is also generally regarded as insignificant. , is the effective thermal resistance between the conductor and the ambient conditions, which can require significant empirical or theoretical effort to estimate. With respect to the AC-sensitive terms, tabular presentation of ...

  9. Help:Convert - Wikipedia

    en.wikipedia.org/wiki/Help:Convert

    By default, the output value is rounded to adjust its precision to match that of the input. An input such as 1234 is interpreted as 1234 ± 0.5, while 1200 is interpreted as 1200 ± 50, and the output value is displayed accordingly, taking into account the scale factor used in the conversion.