When.com Web Search

  1. Ads

    related to: water flow sensor circuit diagram and working machine

Search results

  1. Results From The WOW.Com Content Network
  2. Water detector - Wikipedia

    en.wikipedia.org/wiki/Water_detector

    A water detector is an electronic device that is designed to detect the presence of water for purposes such as to provide an alert in time to allow the prevention of water leakage. A common design is a small cable or device that lies flat on a floor and relies on the electrical conductivity of water to decrease the resistance across two contacts.

  3. Float switch - Wikipedia

    en.wikipedia.org/wiki/Float_switch

    A float switch is a type of level sensor, a device used to detect the level of liquid within a tank. The switch may be used to control a pump, as an indicator, an alarm, or to control other devices. One type of float switch uses a mercury switch inside a hinged float.

  4. Fluidics - Wikipedia

    en.wikipedia.org/wiki/Fluidics

    Fluidic amplifier, showing flow in both states, from U.S. patent 4,000,757. In a fluidic amplifier, a fluid supply, which may be air, water, or hydraulic fluid , enters at the bottom. Pressure applied to the control ports C 1 or C 2 deflects the stream, so that it exits via either port O 1 or O 2 .

  5. Mass flow controller - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_controller

    All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...

  6. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Example of a single industrial control loop; showing continuously modulated control of process flow. Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows:

  7. Magnetic flow meter - Wikipedia

    en.wikipedia.org/wiki/Magnetic_flow_meter

    The magnetic flow meter requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube. If the magnetic field direction were constant, electrochemical and other effects at the electrodes would make the potential difference difficult to distinguish from the ...

  8. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    The diagram to the right shows the design of a basic valve, controlling the flow of water in this example. The top half shows the valve in its closed state. An inlet stream of pressurized water enters at A. B is an elastic diaphragm and above it is a spring pushing it down. The diaphragm has a pinhole through its center which allows a very ...

  9. Ultrasonic flow meter - Wikipedia

    en.wikipedia.org/wiki/Ultrasonic_flow_meter

    Schematic view of a flow sensor. An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and ...