When.com Web Search

  1. Ads

    related to: asme b31.3

Search results

  1. Results From The WOW.Com Content Network
  2. Fluid service of natural gas B31.3 - ASME (mechanical) Code...

    www.eng-tips.com/threads/fluid-service-of-natural-gas-b31-3.198830

    The B31.3 Fluid Service concept considers the fluid contained within the pipe and the particular set of operating circumstances as well as the safeguards that will be in place (see B31.3, Appendix "G"). Natural gas is not TOXIC (albeit, breathing it to exclude oxygen would be harmful), and exposure to very small quantities of natural gas due to ...

  3. ASME B31.3. Welding a weldolet on a reducer? - Eng-Tips

    www.eng-tips.com/threads/asme-b31-3-welding-a-weldolet-on-a-reducer.213911

    You could make an estimate of the strength by using the correct thickness and average diameter of the reducer at the centre line of the weldolet, using ASME B31.3 rules for pressure reinforcement for example .... But you will end up with a horrible weld gap I suspect. SIF's would be questionable too. Better to move it to an adjacent straight ??

  4. ASME B31.8 and B31.3 - ASME (mechanical) Code Issues - Eng-Tips

    www.eng-tips.com/threads/asme-b31-8-and-b31-3.193285

    Also, the types of piping covered by B31.8 (unlike B31.3 piping) is regulated by the Federal Code of Regulations. For contractual purposes, the boundaries of B31.8 above-ground facilities should be established and shown unambiguously on the facility plot plan. Within those boundaries, the rules of B31.8 and Federal Regulations (49CFR192) shall ...

  5. ASME B31.3 PWHT Requirement - ASME (mechanical) Code Issues -...

    www.eng-tips.com/threads/asme-b31-3-pwht-requirement.381691

    3. PK. Please clarify my understanding, that per B31.3- 2014, PWHT is required for all thicknesses per table 331.1.1, while there is exemptions per Table 331.1.3 i.e. for P1 material having thickness greater than 1" PWHT is not required if preheated to 95 C (multiple layer welds t>5mm) and PWHT is required for all thickness lower than 1" for P1 ...

  6. ASME B.31.3 Pressure Test Limits - Eng-Tips

    www.eng-tips.com/threads/asme-b-31-3-pressure-test-limits.217081

    ASME B31.3 calculation for Hydrostatic Pressure Test can be limited follows: (c) if the test pressure as defined above would produce. a nominal pressure stress or longitudinal stress in. excess of the yield strength at test temperature or a. pressure more than 1.5 times the component rating at. test temperature, the test pressure may be reduced to.

  7. ASME B31.3 2024 Public Review Draft 1 - Eng-Tips

    www.eng-tips.com/threads/asme-b31-3-2024-public-review-draft.518178

    (a direct link seems to get invalid every day, so take this link and scroll down until you see B31.3 20xx and a download link underneath). The draft only shows the approved ballots. Public comments may be submitted on proposed new ASME Standards drafts and on proposals to revise, reaffirm, or withdraw approval of existing ASME Standards.

  8. ASME B31.3 Exempt Piping - ASME (mechanical) Code Issues

    www.eng-tips.com/threads/asme-b31-3-exempt-piping.514720

    Chemical. May 16, 2023. 3. US. Hello, I have a vendor claiming the gas piping to a burner is exempt from B31.3 due to the design pressure being 12 PSIG and stream composition being purely natural gas. I looked into the contract code, AMSE B31.3 (1996) and found the following exclusion and definition for flammable.

  9. ASME B31.3 - ASME (mechanical) Code Issues | Eng-Tips

    www.eng-tips.com/threads/asme-b31-3.342432

    I need some help determining the acceptable limits of porosity in B31.3 normal fluid service. Criterion Value Notes for Table 341.3.2 D Size and distribution of internal porosity See BPV Code, Section VIII, Division 1, Appendix 4 E Size and distribution of internal porosity For T w ≤ 6 mm (1⁄4...

  10. ASME B31.3 Acceptance criteria for welds 1 - Eng-Tips

    www.eng-tips.com/threads/asme-b31-3-acceptance-criteria-for-welds.326321

    As per ASME B31.3 Table 341.3.2 Acceptance criteria for welds, is it important to meet all the acceptable values mentioned in the criteria. For eg. lack of root penetration for Normal and Category M fluid - Girth, Miter groove and branch connection shows B as acceptance criteria. Notation B has two acceptable values in the table.

  11. ASME B31.3 Fluid Service for NaOH 1 - Eng-Tips

    www.eng-tips.com/threads/asme-b31-3-fluid-service-for-naoh.79125

    Chemical. Aug 8, 2003. 2. US. I am trying to justify the ASME B31.3 classification of Normal Fluid service for 50% NaOH. The system design gauge pressure is below 150 psi and the design temperature is ambient. Sodium Hydroxide does not produce systemic toxicity; its health effects are due to its corrosive nature.

  1. Ad

    related to: asme b31.3