Results From The WOW.Com Content Network
Variable air volume (VAV) is a type of heating, ventilating, and/or air-conditioning system. Unlike constant air volume (CAV) systems, which supply a constant airflow at a variable temperature, VAV systems vary the airflow at a constant or varying temperature.
A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...
Such a control sequence is supported by a pollutant sensor (e.g. carbon dioxide sensor), a variable frequency drive (VFD) on the fan supplying the zone, individual VAV boxes with reheat serving each space in the zone, and airflow measuring stations. [4] Research has been conducted on the application of DCV in constant-air-volume (CAV) systems.
However, they are seldom used as the actual basis of design or calculation. For example, residential ventilation rates are calculated based on area of the residence and number of occupants. [ 5 ] Non-residential ventilation rates are based on floor area and number of occupants, or a calculated dilution of known contaminants. [ 6 ]
Most new commercial buildings have VAV systems. VAVs may be bypass type or pressure dependent. Pressure dependent type VAVs save energy while both types help in maintaining temperature of the zone that it feeds. Abbreviated VAV. zoning system A zoning system sections a building or a space into zones which are controlled independently of each other.
The starting point in carrying out an estimate both for cooling and heating depends on the exterior climate and interior specified conditions. However, before taking up the heat load calculation, it is necessary to find fresh air requirements for each area in detail, as pressurization is an important consideration.
The total outdoor air intake of the ventilation system (in multiple-zone variable air volume (VAV) systems) might therefore be similar to the airflow required by the 1989 standard. From 1999 to 2010, there was considerable development of the application protocol for ventilation rates.
Center for the Built Environment developed a new index UFAD cooling load ratio (UCLR), which is defined by the ratio of the peak cooling load calculated for UFAD to the peak cooling load calculated for a well-mixed system, to calculate the UFAD cooling load for each zone with the traditional peak cooling load of an overhead (well-mixed) system.