Modern automatic circuit reclosers are significantly more advanced than the original hydraulic units. The advent of semiconductor based electronic protective relays in the 1980s resulted in increased recloser sophistication, allowing for differing responses to the various cases of abnormal operation or fault on an electric power distribution ...
Other standard features include automatic reclosing circuit breakers . Most faults (overcurrent) are transient. Since the network is rural, most of these faults will be cleared by the recloser. Each service site needs a rewirable drop out fuse for protection and switching of the transformer.
In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .
Reclosers are not the only automatic reclosing devices on distribution ciruits; however they can greatly improve overall system reliability by decreasing the amount of customers experiencing an outage for a given fault. — Preceding unsigned comment added by Greyphox (talk • contribs) 03:42, 18 January 2012 (UTC)
Description and definition [ edit ] The digital protective relay is a protective relay that uses a microprocessor to analyze power system voltages, currents or other process quantities for the purpose of detection of faults in an electric power system or industrial process system.
Earth leakage circuit breaker A protective device that opens a circuit when stray voltage or current is detected that would present a hazard of electric shock. eddy current An electric current induced inside a conductor exposed to a changing magnetic field. edge detection An image processing technique used to identify boundaries of objects ...
On-load tap changer (OLTC), also known as On-circuit tap changer (OCTC), is a tap changer in applications where a supply interruption during a tap change is unacceptable, the transformer is often fitted with a more expensive and complex on-load tap changing mechanism. On-load tap changers may be generally classified as either mechanical ...
Examples are a voltage regulator (which can be a transformer whose voltage ratio of transformation can be adjusted, or an electronic circuit that produces a defined voltage), a pressure regulator, such as a diving regulator, which maintains its output at a fixed pressure lower than its input, and a fuel regulator (which controls the supply of ...