When.com Web Search

  1. Ad

    related to: iron standard solution preparation for gc ms system schematic analysis

Search results

  1. Results From The WOW.Com Content Network
  2. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    Sample preparation for mass spectrometry is used for the optimization of a sample for analysis in a mass spectrometer (MS). Each ionization method has certain factors that must be considered for that method to be successful, such as volume, concentration, sample phase, and composition of the analyte solution. Quite possibly the most important ...

  3. Standard solution - Wikipedia

    en.wikipedia.org/wiki/Standard_solution

    Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1] A standard solution ideally has a high degree of purity and is stable enough that the concentration can be accurately measured after a long shelf time. [2]

  4. Matrix (chemical analysis) - Wikipedia

    en.wikipedia.org/wiki/Matrix_(chemical_analysis)

    For example, the ionic strength of the solution can have an effect on the activity coefficients of the analytes. [3] [4] The most common approach for accounting for matrix effects is to build a calibration curve using standard samples with known analyte concentration and which try to approximate the matrix of the sample as much as possible. [2]

  5. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    GCMS is used for the analysis of unknown organic compound mixtures. One critical use of this technology is the use of GCMS to determine the composition of bio-oils processed from raw biomass. [29] GCMS is also utilized in the identification of continuous phase component in a smart material, magnetorheological (MR) fluid. [30]

  6. OpenChrom - Wikipedia

    en.wikipedia.org/wiki/OpenChrom

    OpenChrom is an open source software for the analysis and visualization of mass spectrometric and chromatographic data. [4] Its focus is to handle native data files from several mass spectrometry systems (e.g. GC/MS, LC/MS, Py-GC/MS, HPLC-MS), vendors like Agilent Technologies, Varian, Shimadzu, Thermo Fisher, PerkinElmer and others.

  7. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Similarly to gas chromatography MS (GC-MS), liquid chromatography-mass spectrometry (LC/MS or LC-MS) separates compounds chromatographically before they are introduced to the ion source and mass spectrometer. It differs from GC-MS in that the mobile phase is liquid, usually a mixture of water and organic solvents, instead of gas.

  8. Two-dimensional chromatography - Wikipedia

    en.wikipedia.org/wiki/Two-dimensional_chromatography

    Gas chromatography-mass spectrometry (GC-MS) is a two-dimensional chromatography technique that combines the separation technique of gas chromatography with the identification technique of mass spectrometry. GC-MS is the single most important analytical tool for the analysis of volatile and semi-volatile organic compounds in complex mixtures. [7]

  9. Flame ionization detector - Wikipedia

    en.wikipedia.org/wiki/Flame_ionization_detector

    The design of the flame ionization detector varies from manufacturer to manufacturer, but the principles are the same. Most commonly, the FID is attached to a gas chromatography system. The eluent exits the gas chromatography column (A) and enters the FID detector’s oven (B). The oven is needed to make sure that as soon as the eluent exits ...