Search results
Results From The WOW.Com Content Network
An MRI artifact is a visual artifact (an anomaly seen during visual representation) in magnetic resonance imaging (MRI). It is a feature appearing in an image that is not present in the original object. [1] Many different artifacts can occur during MRI, some affecting the diagnostic quality, while others may be confused with pathology ...
Ghosting is a visual artifact that occurs in magnetic resonance imaging (MRI) scans. This artifact can be a consequence of environmental factors or the human body (such as blood flow, implants, etc.). Ghosting is a multidimensional artifact that occurs in the MRI in the phase-encoded direction (short axis of the image) after applying the ...
In iterative reconstruction in digital imaging, interior reconstruction (also known as limited field of view (LFV) reconstruction) is a technique to correct truncation artifacts caused by limiting image data to a small field of view. The reconstruction focuses on an area known as the region of interest (ROI).
Magnetic resonance imaging (MRI) is a medical imaging technique used in radiology to generate pictures of the anatomy and the physiological processes inside the body. MRI scanners use strong magnetic fields , magnetic field gradients, and radio waves to form images of the organs in the body.
The gray spot in the center is a shadow artifact. Image quality factors, different types of visual artifacts; Compression artifacts; Digital artifacts, visual artifacts resulting from digital image processing; Noise; Screen-door effect, also known as fixed-pattern noise (FPN), a visual artifact of digital projection technology; Ghosting ...
A conventional gradient echo T2*-weighted image (left, TE=20 ms) shows some low-signal foci associated with CAA. On the other hand, an SWI image (center, with a resolution of 0.5 mm x 0.5 mm x 2.0 mm, projected over 8mm) shows many more associated low-signal foci. Phase images were used to enhance the effect of the local hemosiderin build-up.
In vivo magnetic resonance spectroscopy (MRS) is a specialized technique associated with magnetic resonance imaging (MRI). [1] [2]Magnetic resonance spectroscopy (MRS), also known as nuclear magnetic resonance (NMR) spectroscopy, is a non-invasive, ionizing-radiation-free analytical technique that has been used to study metabolic changes in brain tumors, strokes, seizure disorders, Alzheimer's ...
The magic angle artifact refers to the increased signal observed when MRI sequences with short echo time (TE) (e.g., T 1 or proton density spin-echo sequences) are used to image tissues with well-ordered collagen fibers in one direction (e.g., tendon or articular hyaline cartilage). [1]