Apart from testing binocular functions, Bagolini striated glasses can measure cyclotropia.The principle of the test is similar to that of double Maddox rod test. The glasses are placed in the trial frames with the striations vertical, giving rise to two horizontal line images when viewing a spotlight.
The test is based on the principle of diplopic projection. [1] Dissociation of the deviation is brought about by presenting a red line image to one eye and a white light to the other, while prisms are used to superimpose these and effectively measure the angle of deviation (horizontal and vertical).
A cover test or cover-uncover test is an objective determination of the presence and amount of ocular deviation. It is typically performed by orthoptists, ophthalmologists and optometrists during eye examinations. The two primary types of cover tests are: the alternating cover test; the unilateral cover test (or the cover-uncover test).
Diplopia is the simultaneous perception of two images of a single object that may be displaced in relation to each other. [1] Also called double vision , it is a loss of visual focus under regular conditions, and is often voluntary.
Young children with strabismus normally suppress the visual field of one eye (or part of it), whereas adults who develop strabismus normally do not suppress and therefore suffer from double vision . This also means that adults (and older children) have a higher risk of post-operative diplopia after undergoing strabismus surgery than young children.
The Worth Four Light Test, also known as the Worth's four dot test or W4LT, is a clinical test mainly used for assessing a patient's degree of binocular vision and binocular single vision. Binocular vision involves an image being projected by each eye simultaneously into an area in space and being fused into a single image.
Requires a higher level of patient understanding and concentration compared to other visual field tests [9] Time-consuming; Learning effect: new patients improve as more tests are performed due to understanding of the test conditions. Consider the third test as the baseline result [23] Potential for artefacts (i.e. uncharacteristic vision loss ...
The Maddox Wing test is performed at near with the instrument held in reading position, slightly inferior (approximately 15° depression and 33 cm away). The room or location of the test should be brightly illuminated and the patient's optical correction (e.g. glasses, bifocals, multifocals, contact lens) is required to be worn.