  1. Results From The WOW.Com Content Network
  2. Grounding resistance tester - Wikipedia

    en.wikipedia.org/wiki/Grounding_resistance_tester

    The first soil resistance measuring instrument was invented in the 1950s by Evershed & Vignoles Meggers who made the first insulation and earth resistance testers. [2] One of the most used analog grounding testers in USSR were М416. [3] From the 21st century several companies produced digital earth resistance meters and testers.

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    A good earth connection is normally a 6 m stake of copper-clad steel driven vertically into the ground, and bonded to the transformer earth and tank. A good ground resistance is 5–10 ohms which can be measured using specialist earth test equipment.

  4. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.

  5. Electrical resistance survey - Wikipedia

    en.wikipedia.org/wiki/Electrical_resistance_survey

    Electrical resistance survey of an archaeological site using a twin probe system. In most systems, metal probes (electrodes) are inserted into the ground to obtain a reading of the local electrical resistance. A variety of probe configurations are used, most having four probes, often mounted on a rigid frame. In these systems, two of the probes ...

  6. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  7. Megohmmeter - Wikipedia

    en.wikipedia.org/wiki/Megohmmeter

    Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

  8. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high-voltage source and voltage and current meters. A single instrument called a "pressure test set" or "hipot tester" is often used to perform this test.

  9. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    A digital clamp meter A multimeter with built-in clamp. Pushing the large button at the bottom opens the lower jaw of the clamp, allowing the clamp to be placed around a conductor. An electrical meter with integral AC current clamp is known as a clamp meter, clamp-on ammeter, tong tester, or colloquially as an amp clamp.