When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Beer–Lambert law - Wikipedia

    en.wikipedia.org/wiki/BeerLambert_law

    The extinction law's primary application is in chemical analysis, where it underlies the BeerLambert law, commonly called Beer's law. Beer's law states that a beam of visible light passing through a chemical solution of fixed geometry experiences absorption proportional to the solute concentration .

  3. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    The absorbance of a material that has only one absorbing species also depends on the pathlength and the concentration of the species, according to the BeerLambert law =, where ε is the molar absorption coefficient of that material; c is the molar concentration of those species; ℓ is the path length.

  4. Mathematical descriptions of opacity - Wikipedia

    en.wikipedia.org/wiki/Mathematical_descriptions...

    An electromagnetic wave propagating in the +z-direction is conventionally described by the equation: (,) = ⁡ [()], where E 0 is a vector in the x-y plane, with the units of an electric field (the vector is in general a complex vector, to allow for all possible polarizations and phases);

  5. Absorption (electromagnetic radiation) - Wikipedia

    en.wikipedia.org/wiki/Absorption_(electromagnetic...

    This may be related to other properties of the object through the BeerLambert law. Precise measurements of the absorbance at many wavelengths allow the identification of a substance via absorption spectroscopy, where a sample is illuminated from one side, and the intensity of the light that exits from the sample in every direction is measured.

  6. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    The BeerLambert law states that there is a logarithmic dependence between the transmission (or transmissivity), T, of light through a substance and the product of the absorption coefficient of the substance, α, and the distance the light travels through the material (i.e. the path length), ℓ.

  7. Atomic absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Atomic_absorption_spectroscopy

    The difference in intensity is directly proportional to the concentration of the analyte in the sample, following the Beer-Lambert law: * **A = εcl**, where: * A is the absorbance measured. * ε is the molar absorptivity (constant specific to the element and wavelength). * c is the concentration of the analyte.

  8. Attenuation length - Wikipedia

    en.wikipedia.org/wiki/Attenuation_length

    In physics, the attenuation length or absorption length is the distance λ into a material when the probability has dropped to 1/e that a particle has not been absorbed. ...

  9. Colorimeter (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Colorimeter_(chemistry)

    A colorimeter is a device used in colorimetry that measures the absorbance of particular wavelengths of light by a specific solution. [1] [2] It is commonly used to determine the concentration of a known solute in a given solution by the application of the BeerLambert law, which states that the concentration of a solute is proportional to the absorbance.