When.com Web Search

  1. Ads

    related to: ground fault outlet problems

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  5. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    This may lead to ground faults on variable speed drives between the drive electronics and motor not being detected for example. Disadvantages of voltage-sensing devices over current-sensing: A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices.

  6. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.

  7. Stray voltage - Wikipedia

    en.wikipedia.org/wiki/Stray_voltage

    Toronto Hydro pulled all employees off regular duty on the weekend of January 30, 2009 to deal with ongoing stray voltage problems in the city. [26] This came after as many as five children were shocked [27] though none suffered serious injury. The stray voltage problem had claimed the lives of two dogs in the previous few months. [28]

  8. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    A ground conductor only carries significant current if there is a circuit fault that would otherwise energize exposed conductive parts and present a shock hazard. In that case, circuit protection devices may detect a fault to a grounded metal enclosure and automatically de-energize the circuit, or may provide a warning of a ground fault.

  9. Overcurrent - Wikipedia

    en.wikipedia.org/wiki/Overcurrent

    Possible causes for overcurrent include short circuits, excessive load, incorrect design, an arc fault, or a ground fault. Fuses, circuit breakers, and current limiters are commonly used overcurrent protection (OCP) mechanisms to control the risks. Circuit breakers, relays, and fuses protect circuit wiring from damage caused by overcurrent. [1]