Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.
A register's damper provides a critical function. Primarily, the damper allows the amount of hot or cool air entering a room to be controlled, providing for more accurate control over room temperature. [7] Dampers also allow air to be shut off in unused rooms, improving the efficiency of the HVAC system.
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
smoke damper A damper or adjustable louver designed to augment the ventilation of a space during a fire. split system A split system is the combination of an outdoor unit and an indoor unit. This is the most common type of system. superheat The number of degrees a vapor is above its boiling point at a specific pressure. subcooling
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...
The temperature rise is not significantly affected by the perimeter zone orientation, the internal heat gain and the window-to-wall ratio. [16] Supply plenum air temperature rise, thus, has implications on the energy saving potential of UFAD systems and their ability to meet cooling requirements with supply temperatures above those of ...
After the control of air flow and temperature was standardized, the use of electromechanical relays in ladder logic to switch dampers became standardized. Eventually, the relays became electronic switches, as transistors eventually could handle greater current loads. By 1985, pneumatic controls could no longer compete with this new technology ...