Search results
Results From The WOW.Com Content Network
Two thermal switches (Thermal Cut) Schematic symbol for a thermal overload switch. A thermal switch (sometimes thermal reset or thermal cutout (TCO)) is a device which normally opens at a high temperature (often with a faint "plink" sound) and re-closes when the temperature drops. The thermal switch may be a bimetallic strip, often encased in a ...
power engineering That part of electrical engineering that deals with the generation, distribution and consumption of electrical power. power-factor correction Apparatus intended to bring the power factor of some load closer to 1. power factor The ratio of apparent power flowing to a load divided by the real power. power-flow study
External Device Monitor (EDM). The device issuing the OSSD signals may have an EDM input. The EDM is used to verify that the controlled device (safety relay) did indeed open when the OSSD signals were dropped. The safety relay has normally closed contacts, which close when the relay is de-energized, thereby turning on the EDM input.
Each key of a computer keyboard, for example, is a normally-open "push-to-make" switch. A "push-to-break" (or normally-closed or NC) switch, on the other hand, breaks contact when the button is pressed and makes contact when it is released. An example of a push-to-break switch is a button used to release a door held closed by an electromagnet.
The National Association of Relay Manufacturers and its successor, the Relay and Switch Industry Association define 23 distinct forms of electrical contact found in relays and switches. [ 12 ] A normally closed ( NC ) contact pair is closed (in a conductive state) when it, or the device operating it, is in a deenergized state or relaxed state.
Figure lA illustrates a single-pole, single-throw normally open switch (SPST NO). Figure 1B shows a single-pole, double-throw (SPDT) switch. One terminal is normally-open (NO) and the other is normally-closed (NC). Depending on the state of the switch, one or the other position is connected to the common terminal (COM).
A smaller unit which simulates a complete unit or element in an electrical test, without reducing the severity of the electrical, thermal or mechanical conditions. [v] multi-connected converter A converter consisting of two or more converter units parallel connected or series connected or both, each of which is an operative converter of its own.
2 out 82 lock in 82a 1st out 82b 2nd out 82z 1st in 82y 2nd in 83 multi position switch, in 83a out position 1 83b out position 2 Relay; 85 relay coil - Important if relay coil has flyback diode in parallel 86 relay coil + Important if relay coil has diode in parallel Relay contacts 87 common contact 30/51 87a normally closed contact 87b