  1. Results From The WOW.Com Content Network
  2. Intrinsic safety - Wikipedia

    en.wikipedia.org/wiki/Intrinsic_safety

    Intrinsically safe mobile phones must meet special battery design criteria in order to achieve UL, ATEX directive, or IECEx certification for use in explosive atmospheres. Only properly designed battery-operated, self-contained devices can be intrinsically safe by themselves. Other field devices and wiring are intrinsically safe only when ...

  3. Electrical equipment in hazardous areas - Wikipedia

    en.wikipedia.org/wiki/Electrical_equipment_in...

    Unlike ATEX which uses numbers to define the safety "Category" of equipment (namely 1, 2, and 3), the IEC continued to utilise the method used for defining the safe levels of intrinsic safety namely "a" for zone 0, "b" for zone 1 and "c" for zone 2 and apply this Equipment Level of Protection to all equipment for use in hazardous areas since ...

  4. Inherent safety - Wikipedia

    en.wikipedia.org/wiki/Inherent_safety

    (Kletz originally used the term intrinsically safe in 1978, but as this had already been used for the special case of electronic equipment in potentially flammable atmospheres, only the term inherent was adopted. Intrinsic safety may be considered a special subset of inherent safety). In 2010 the American Institute of Chemical Engineers ...

  5. Circuit integrity - Wikipedia

    en.wikipedia.org/wiki/Circuit_integrity

    Circuit integrity describes the extent of a fire's effect on an electrical circuit's operation. It is a form of fire-resistance rating . Circuit integrity is achieved via passive fire protection means, which are subject to listing and approval use and compliance .

  6. Electrical safety standards - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_standards

    In 1994 were established Electrical Safety Foundation International non-profit organization dedicated exclusively to promoting electrical safety at home and in the workplace. [ 3 ] Standard 29 CFR 1910.269 – for electric power generation, transmission, and distribution, contained comprehensive regulations and addressed control of hazardous ...

  7. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is also used to define a type of overcurrent protective device.

  8. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  9. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power outlet can rise relative to the local earth (concrete floor, water pipe etc.) to a ...