When.com Web Search

  1. Ads

    related to: 3 phase generator sizing calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three-phase motors also vibrate less and hence last longer than single-phase motors of the same power used under the same conditions. [32]

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    For example, balanced two-phase power can be obtained from a three-phase network by using two specially constructed transformers, with taps at 50% and 86.6% of the primary voltage. This Scott T connection produces a true two-phase system with 90° time difference between the phases.

  4. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    Capacitive current Ic = Q/E = 1523/440 = 3.46 A Capacitive reactance per phase Xc = E/Ic = 127 Ω. Minimum capacitance per phase: C = 1 / (2*π*f*Xc) = 1 / (2 * 3.141 * 60 * 127) = 21 μF. If the load also absorbs reactive power, capacitor bank must be increased in size to compensate. Prime mover speed should be used to generate frequency of 60 Hz:

  5. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  6. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    One voltage cycle of a three-phase system. A polyphase system (the term coined by Silvanus Thompson) is a means of distributing alternating-current (AC) electrical power that utilizes more than one AC phase, which refers to the phase offset value (in degrees) between AC in multiple conducting wires; phases may also refer to the corresponding terminals and conductors, as in color codes.

  7. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    The tie-in panel may also contain a phase rotation indicator (for 3-phase systems) and a circuit breaker. Camlock connectors are rated for 400 amps up to 480-volt systems and used with 4/0 type W cable connecting to the generator. Tie-in panel designs are common between 200- and 3000-amp applications.

  1. Ad

    related to: 3 phase generator sizing calculator