Search results
Results From The WOW.Com Content Network
Demand Valve Oxygen Therapy (DVOT) is a way of delivering high flow oxygen therapy using a device that only delivers oxygen when the patient breathes in and shuts off when they breathe out. DVOT is commonly used to treat conditions such as cluster headache , which affects up to four in 1000 people (0.4%), [ 1 ] [ 2 ] [ 3 ] and is a recommended ...
Devices with a demand valve are available for self-administration. [5] The setup and maintenance is relatively expensive for developing countries. [6] [7] There are few side effects, other than vomiting, with short-term use. [1] [2] With long-term use anemia or numbness may occur. [2] It should always be given with at least 21% oxygen. [2]
The device must have a pressure relief valve that opens at 60cm of water pressure to avoid over ventilation and trauma to the lungs. The (FROPVD) is contraindicated in adult patients with potential chest trauma and all children. Note: ( In cases with an apneic patient the best results will be achieved using the Two person bag-valve-mask technique.)
Demand: 2000 psi to the regulator from the main valve, plus a bypass valve in case of failure, with a two-stage regulator reducing pressure to 50-100 psi. Pressure-Demand : Similar to demand, but with a spring in the diaphragm, which holds the admission valve open, for continuous air flow to the facepiece.
Based on experience gained from analysis of mishaps, the modern anaesthetic machine incorporates several safety devices, including: an oxygen failure alarm (a.k.a. 'Oxygen Failure Warning Device' or OFWD). In older machines this was a pneumatic device called a Ritchie whistle which sounds when oxygen pressure is 38 psi descending.
A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. [citation needed] There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank.
demand valve A demand valveis a flow control mechanism that detects a pressure drop on the downstream side and opens the valve to compensate for the pressure drop. In supplied gas breathing apparatus this provides the user with a breath of gas at approximately the pressure set and maintained within the facepiece.
They include over-sedation, respiratory depression/apnoea, unconscious patient, airway obstruction, vomiting, idiosyncratic responses, delayed recovery, and failure of conscious sedation. [ 3 ] Few absolute contraindications exist, however, "relative contraindications are important and can only be considered following a full assessment."