The number of transfer units (NTU) method is used to calculate the rate of heat transfer in heat exchangers (especially parallel flow, counter current, and cross-flow exchangers) when there is insufficient information to calculate the log mean temperature difference (LMTD). Alternatively, this method is useful for determining the expected heat ...
When one fluid flows through the smaller pipe, the other flows through the annular gap between the two pipes. These flows may be parallel or counter-flows in a double pipe heat exchanger. (a) Parallel flow, where both hot and cold liquids enter the heat exchanger from the same side, flow in the same direction and exit at the same end.
Cocurrent and countercurrent heat exchange. A cocurrent heat exchanger is an example of a cocurrent flow exchange mechanism. Two tubes have a liquid flowing in the same direction. One starts off hot at 60 °C (140 °F), the second cold at 20 °C (68 °F). A thermoconductive membrane or an open section allows heat transfer between the two flows.
In parallel flow, fluids enter the heat exchanger through their tubes, and the fluids flow in the same direction. In counterflow, the fluids flow in opposing directions. Counterflow provides the most efficient transfer of heat, as it is able to transfer the most heat from the heat transfer medium. Cross-flow has fluids travel perpendicular to ...
Types of recuperator, or cross plate heat exchanger. A recuperator (electro- end carbogidro-) - is a special purpose counter-flow energy recovery heat exchanger positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, in order to recover the waste heat. Generally, they are ...
Q is the exchanged heat duty , U is the heat transfer coefficient (watts per kelvin per square meter), A is the exchange area. Note that estimating the heat transfer coefficient may be quite complicated. This holds both for cocurrent flow, where the streams enter from the same end, and for countercurrent flow, where they enter from different ends.
One common example of a heat exchanger is a car's radiator, in which the hot coolant fluid is cooled by the flow of air over the radiator's surface. [34] [35] Common types of heat exchanger flows include parallel flow, counter flow, and cross flow.
The statement of Newton's law used in the heat transfer literature puts into mathematics the idea that the rate of heat loss of a body is proportional to the difference in temperatures between the body and its surroundings. For a temperature-independent heat transfer coefficient, the statement is: