Search results
Results From The WOW.Com Content Network
The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve .
Paschen's law is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. [2] [3] It is named after Friedrich Paschen who discovered it empirically in 1889. [4]
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
Mass transfer coefficients can be estimated from many different theoretical equations, correlations, and analogies that are functions of material properties, intensive properties and flow regime (laminar or turbulent flow). Selection of the most applicable model is dependent on the materials and the system, or environment, being studied.
The general time- and transfer-constants (TTC) analysis [1] is the generalized version of the Cochran-Grabel (CG) method, [2] which itself is the generalized version of zero-value time-constants (ZVT), which in turn is the generalization of the open-circuit time constant method (OCT). [3]
The vaporizing droplet (droplet vaporization) problem is a challenging issue in fluid dynamics.It is part of many engineering situations involving the transport and computation of sprays: fuel injection, spray painting, aerosol spray, flashing releases…
Gas blending for surface supplied and saturation diving may include the filling of bulk storage cylinders and bailout cylinders with breathing gases, but it also involves the mixing of breathing gases at lower pressure which are supplied directly to the diver or to the hyperbaric life-support system. Part of the operation of the life-support ...
The curve is typically plotted alongside the open-circuit saturation curve. [1] The SCC is almost linear, since under the short-circuit conditions the magnetic flux in the generator is below the iron saturation levels and thus the reluctance is almost entirely defined by the fixed one of the air gap.