When.com Web Search

  1. Ads

    related to: temperature control loop p&id 5 pack manual

Search results

  1. Results From The WOW.Com Content Network
  2. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Example of a single industrial control loop; showing continuously modulated control of process flow. Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows:

  3. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    The PID loop in this situation uses the feedback information to change the combined output to reduce the remaining difference between the process setpoint and the feedback value. Working together, the combined open-loop feed-forward controller and closed-loop PID controller can provide a more responsive control system.

  4. Control loop - Wikipedia

    en.wikipedia.org/wiki/Control_loop

    A control loop is the fundamental building block of control systems in general and industrial control systems in particular. It consists of the process sensor, the controller function, and the final control element (FCE) which controls the process necessary to automatically adjust the value of a measured process variable (PV) to equal the value of a desired set-point (SP).

  5. Ziegler–Nichols method - Wikipedia

    en.wikipedia.org/wiki/Ziegler–Nichols_method

    The "P" (proportional) gain, is then increased (from zero) until it reaches the ultimate gain, at which the output of the control loop has stable and consistent oscillations. K u {\displaystyle K_{u}} and the oscillation period T u {\displaystyle T_{u}} are then used to set the P, I, and D gains depending on the type of controller used and ...

  6. Setpoint (control system) - Wikipedia

    en.wikipedia.org/wiki/Setpoint_(control_system)

    A setpoint can be any physical quantity or parameter that a control system seeks to regulate, such as temperature, pressure, flow rate, position, speed, or any other measurable attribute. In the context of PID controller , the setpoint represents the reference or goal for the controlled process variable.

  7. Closed-loop controller - Wikipedia

    en.wikipedia.org/wiki/Closed-loop_controller

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.