When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  3. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  4. Table of thermodynamic equations - Wikipedia

    en.wikipedia.org/wiki/Table_of_thermodynamic...

    Quantity (common name/s) (Common) symbol/s Defining equation SI unit Dimension Temperature gradient: No standard symbol K⋅m −1: ΘL −1: Thermal conduction rate, thermal current, thermal/heat flux, thermal power transfer

  5. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  6. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    The U-factor or U-value (in W/(m 2 ⋅K)) is the overall heat transfer coefficient and can be found by taking the inverse of the R-value. It is a property that describes how well building elements conduct heat per unit area across a temperature gradient.

  7. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units.

  8. List of thermal conductivities - Wikipedia

    en.wikipedia.org/wiki/List_of_thermal_conductivities

    Instead the formula that would fit some of the Bonales data is k ≈ 2.0526 - 0.0176TC and not k = -0.0176 + 2.0526T as they say on page S615 and also the values they posted for Alexiades and Solomon do not fit the other formula that they posted on table 1 on page S611 and the formula that would fit over there is k = 2.18 - 0.01365TC and not k ...

  9. List of physical constants - Wikipedia

    en.wikipedia.org/wiki/List_of_physical_constants

    The constants listed here are known values of physical constants expressed in SI units; that is, physical quantities that are generally believed to be universal in nature and thus are independent of the unit system in which they are measured. Many of these are redundant, in the sense that they obey a known relationship with other physical ...