When.com Web Search

  1. Ad

    related to: how to terminate rg6 cable box with 4

Search results

  1. Results From The WOW.Com Content Network
  2. Electrical termination - Wikipedia

    en.wikipedia.org/wiki/Electrical_termination

    A terminating resistor for a television coaxial cable is often in the form of a cap, threaded to screw onto an F connector. Antenna cables are sometimes used for internet connections; however, RG-6 should not be used for 10BASE2 (which should use RG-58) as the impedance mismatch can cause phasing problems with the baseband signal.

  3. Modular connector - Wikipedia

    en.wikipedia.org/wiki/Modular_connector

    A cable wired as T568A at one end and wired as T568B at the other end (Tx and Rx pairs reversed) is an Ethernet crossover cable. Before the widespread acceptance of auto MDI-X capabilities, a crossover cable was needed to interconnect similar network equipment (such as Ethernet hubs to Ethernet hubs). Crossover cables are sometimes still used ...

  4. F connector - Wikipedia

    en.wikipedia.org/wiki/F_connector

    The F connector (also F-type connector) is a coaxial RF connector commonly used for "over the air" terrestrial television, cable television and universally for satellite television and cable modems, usually with RG-6/U cable or with RG-59/U cable.

  5. Fiber cable termination - Wikipedia

    en.wikipedia.org/wiki/Fiber_cable_termination

    Once the appropriate connector has been identified, the termination process can begin. Common termination methods include no-epoxy-no-polish, epoxy and polish and pigtail splicing. [2] Regardless of the method, the beginning steps are the same. First, the sleeve, or secondary coating, must be stripped from the fiber. The primary coating must ...

  6. RG-6 - Wikipedia

    en.wikipedia.org/wiki/RG-6

    The number was assigned sequentially. The RG unit indicator is no longer part of the JETDS system (MIL-STD-196E) and cable sold today under the RG-6 label is unlikely to meet military specifications. In practice, the term RG-6 is generally used to refer to coaxial cables with an 18 AWG (1.024 mm) center conductor and 75 ohm characteristic ...

  7. Telecommunications pedestal - Wikipedia

    en.wikipedia.org/wiki/Telecommunications_pedestal

    Pedestals are used for CATV (known as a cable box in such a situation), telephone, passive optical networks, and other telecommunications systems. A pedestal is generally a sheet metal or plastic housing that encloses a passive termination block. The pedestal is usually about 3 feet high and has a diameter of less than one foot, with a circular ...

  8. BNC connector - Wikipedia

    en.wikipedia.org/wiki/BNC_connector

    Typically the male connector is fitted to a cable, and the female to a panel on equipment. Cable connectors are often designed to be fitted by crimping [9] using a special power or manual tool. [10] [failed verification] Wire strippers which strip outer jacket, shield braid, and inner dielectric to the correct lengths in one operation are used ...

  9. 110 block - Wikipedia

    en.wikipedia.org/wiki/110_block

    A 110 punch block. A 110 block is a type of punch-down block used to terminate runs of on-premises wiring in a structured cabling system. The designation 110 is also used to describe a type of insulation displacement contact (IDC) connector used to terminate twisted pair cables, [1] which uses a punch-down tool similar to the type used for the older 66 block.