When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Corrosion monitoring - Wikipedia

    en.wikipedia.org/wiki/Corrosion_monitoring

    Corrosion monitoring is the use of a corrator (corrosion meter) or set of methods [1] and equipment to provide offline or online information about corrosion rate expressed in mpy (mill per year). [ 2 ] - for better care and to take or improve preventive measures to combat and protect against corrosion .

  3. Pilling–Bedworth ratio - Wikipedia

    en.wikipedia.org/wiki/Pilling–Bedworth_ratio

    N.B. Pilling and R.E. Bedworth [2] suggested in 1923 that metals can be classed into two categories: those that form protective oxides, and those that cannot. They ascribed the protectiveness of the oxide to the volume the oxide takes in comparison to the volume of the metal used to produce this oxide in a corrosion process in dry air.

  4. Corrosion - Wikipedia

    en.wikipedia.org/wiki/Corrosion

    The rate of corrosion (R) is calculated as = where k is a constant, W is the weight loss of the metal in time t, A is the surface area of the metal exposed, and ρ is the density of the metal (in g/cm 3). Other common expressions for the corrosion rate is penetration depth and change of mechanical properties.

  5. Tribocorrosion - Wikipedia

    en.wikipedia.org/wiki/Tribocorrosion

    In such a case, the total material loss due to tribocorrosion will be much higher than the sum of wear and corrosion one would measure in experiments with the same metal where only wear or only corrosion takes place. The example illustrates the fact that the rate of tribocorrosion is not simply the addition of the rate of wear and the rate of ...

  6. Nernst–Planck equation - Wikipedia

    en.wikipedia.org/wiki/Nernst–Planck_equation

    The Nernst–Planck equation is a conservation of mass equation used to describe the motion of a charged chemical species in a fluid medium. It extends Fick's law of diffusion for the case where the diffusing particles are also moved with respect to the fluid by electrostatic forces.

  7. Piping corrosion circuit - Wikipedia

    en.wikipedia.org/wiki/Piping_corrosion_circuit

    This analysis is performed on circuit inspection results to determine and optimize circuit corrosion rates and measured thickness/dates for circuit components. Corrosion Circuits are utilized in the Integrity Management Plan (IMP) which forms a part of the overall Asset integrity management system and is an integral part of any RBI analysis ...

  8. Pourbaix diagram - Wikipedia

    en.wikipedia.org/wiki/Pourbaix_diagram

    Pourbaix diagram of iron. [1] The Y axis corresponds to voltage potential. In electrochemistry, and more generally in solution chemistry, a Pourbaix diagram, also known as a potential/pH diagram, E H –pH diagram or a pE/pH diagram, is a plot of possible thermodynamically stable phases (i.e., at chemical equilibrium) of an aqueous electrochemical system.

  9. Volatile corrosion inhibitor - Wikipedia

    en.wikipedia.org/wiki/Volatile_corrosion_inhibitor

    NACE International Standard TM0208 defines volatile corrosion inhibitor (VCI) as a chemical substance that acts to reduce corrosion by a combination of volatilization from a VCI material, vapor transport in the atmosphere of an enclosed environment, and condensation onto surface in the space, including absorption, dissolution, and hydrophobic ...