When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.

  3. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.

  4. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.

  5. Parity drive - Wikipedia

    en.wikipedia.org/wiki/Parity_Drive

    A parity drive is a hard drive used in a RAID array to provide fault tolerance. For example, RAID 3 uses a parity drive to create a system that is both fault tolerant and, because of data striping, fast. [1] Basically, a single data bit is added to the end of a data block to ensure the number of bits in the message is either odd or even. [2]

  6. Non-standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Non-standard_RAID_levels

    RAID 5E, RAID 5EE, and RAID 6E (with the added E standing for Enhanced) generally refer to variants of RAID 5 or 6 with an integrated hot-spare drive, where the spare drive is an active part of the block rotation scheme. This spreads I/O across all drives, including the spare, thus reducing the load on each drive, increasing performance.

  7. Error recovery control - Wikipedia

    en.wikipedia.org/wiki/Error_recovery_control

    The result is increased reliability in a RAID array. In a stand-alone configuration TLER should be disabled. As the drive is not redundant, reporting segments as failed will only increase manual intervention. Without a hardware RAID controller or a software RAID implementation to drop the disk, normal (no TLER) recovery ability is most stable.

  8. Category:Fault-tolerant computer systems - Wikipedia

    en.wikipedia.org/wiki/Category:Fault-tolerant...

    RAID (32 P) U. Uninterruptible power supply (7 P, 1 F) Pages in category "Fault-tolerant computer systems" The following 72 pages are in this category, out of 72 total.

  9. Category:Fault tolerance - Wikipedia

    en.wikipedia.org/wiki/Category:Fault_tolerance

    Main page; Contents; Current events; Random article; About Wikipedia; Contact us; Help; Learn to edit; Community portal; Recent changes; Upload file