When.com Web Search

  1. Ads

    related to: 3 phase delta high leg hvac unit for sale philippines

Search results

  1. Results From The WOW.Com Content Network
  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Where the three-phase load is small relative to the total load, two individual transformers may be used instead of the three for a full delta or a three-phase transformer, thus providing a variety of voltages at a reduced cost. This is called open-delta high-leg, and has a reduced capacity relative to a full delta. [3] [4] [5]

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Except in a high-leg delta system and a corner-grounded delta system, single-phase loads may be connected across any two phases, or a load can be connected from phase to neutral. [28] Distributing single-phase loads among the phases of a three-phase system balances the load and makes most economical use of conductors and transformers.

  4. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    The delta winding allows third-harmonic currents to circulate within the transformer, and prevents third-harmonic currents from flowing in the supply line. [2] Delta-wye transformers introduce a 30, 150, 210, or 330 degree phase shift. [3] Thus they cannot be paralleled with wye-wye (or delta-delta) transformers.

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...

  6. Talk:High-leg delta - Wikipedia

    en.wikipedia.org/wiki/Talk:High-leg_delta

    The purpose of using high leg may sometimes be to provide for a small 3-phase load along with substantial single-phase loads, for which open delta works well. When the 3-phase load is large, all three are needed. I have seen more instances of open delta high-leg than with the full 3 transformers or 3-winding transformer.

  7. National Grid Corporation of the Philippines - Wikipedia

    en.wikipedia.org/wiki/National_Grid_Corporation...

    The consortium of Monte Oro Grid Resources Corp., led by businessman Enrique Razon, comprising the State Grid Corporation of China, and Calaca High Power Corp., won in an auction conducted by the Power Sector Assets and Liabilities Management (PSALM) Corp. as it submitted the highest offer of $3.95 billion, for the right to operate TransCo for ...

  8. Air source heat pump - Wikipedia

    en.wikipedia.org/wiki/Air_source_heat_pump

    Heat pump on balcony of apartment. An air source heat pump (ASHP) is a heat pump that can absorb heat from air outside a building and release it inside; it uses the same vapor-compression refrigeration process and much the same equipment as an air conditioner, but in the opposite direction.

  9. File:High leg delta.svg - Wikipedia

    en.wikipedia.org/wiki/File:High_leg_delta.svg

    Phases a, b, and c provide three-phase 240 V power; while phases a and c each provide single-phase 120 V power from the shared neutral n, or split-phase 240 V power between each other. Phase b is known as the "high" or "wild" leg, running at 208 V relative to neutral.