When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Mean airway pressure - Wikipedia

    en.wikipedia.org/wiki/Mean_airway_pressure

    Mean airway pressure typically refers to the mean pressure applied during positive-pressure mechanical ventilation. Mean airway pressure correlates with alveolar ventilation, arterial oxygenation, [1] hemodynamic performance, and barotrauma. [2] It can also match the alveolar pressure if there is no difference between inspiratory and expiratory ...

  3. Montevideo units - Wikipedia

    en.wikipedia.org/wiki/Montevideo_units

    Peak uterine pressure amplitudes were 50 mmHg; during the 10 minute period of measurement 3 contractions occurred; subtract the resting tone from the peak intensity of the contraction; add the 3 contractions together to get the MVUs; Montevideo units are calculated by obtaining the peak uterine pressure amplitude and subtracting the resting tone.

  4. Dynamic pressure - Wikipedia

    en.wikipedia.org/wiki/Dynamic_pressure

    Dynamic pressure is one of the terms of Bernoulli's equation, which can be derived from the conservation of energy for a fluid in motion. [1] At a stagnation point the dynamic pressure is equal to the difference between the stagnation pressure and the static pressure, so the dynamic pressure in a flow field can be measured at a stagnation point ...

  5. Mass flow rate - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_rate

    The area required to calculate the mass flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface, e.g. for substances passing through a filter or a membrane, the real surface is the (generally curved) surface area of the filter, macroscopically - ignoring the area spanned by the holes in the filter/membrane ...

  6. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Hydrogen-cooled turbo generator's cooling can be improved by increasing the hydrogen pressure, larger generators, from 300 MVA, use more efficient water cooling. [3] Capability curve of a synchronous generator with minimum load. The practical D-curve of a typical synchronous generator has one more limitation, minimum load. The minimum real ...

  7. Half time (physics) - Wikipedia

    en.wikipedia.org/wiki/Half_time_(physics)

    The voltage (v) on the capacitor (C) changes with time as the capacitor is charged or discharged via the resistor (R) In electronics, when a capacitor is charged or discharged via a resistor, the voltage on the capacitor follows the above formula, with the half time approximately equal to 0.69 times the time constant, which is equal to the product of the resistance and the capacitance.

  8. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  9. Discharge coefficient - Wikipedia

    en.wikipedia.org/wiki/Discharge_coefficient

    In a nozzle or other constriction, the discharge coefficient (also known as coefficient of discharge or efflux coefficient) is the ratio of the actual discharge to the ideal discharge, [1] i.e., the ratio of the mass flow rate at the discharge end of the nozzle to that of an ideal nozzle which expands an identical working fluid from the same initial conditions to the same exit pressures.