When.com Web Search

  1. Ads

    related to: draft inducing fans chimney pipe insulation system cost estimate sheet

Search results

  1. Results From The WOW.Com Content Network
  2. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    Normally it is done with the help of a forced draft fan. [2] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure. In this case, the system is said to operate under induced draft. The stacks (or chimneys) provide sufficient natural draft to meet the low draft loss needs.

  3. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The draft (draught in British English) flow rate induced by the stack effect can be calculated with the equation presented below. [12] [13] The equation applies only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building and A is the flow area of the openings.

  4. Passive ventilation - Wikipedia

    en.wikipedia.org/wiki/Passive_ventilation

    Typical modern mechanical ventilation systems use as little as 2000 J/m 3 for fan operation, and in cold weather they can recover much more energy than this in the form of heat transferred from waste exhaust air to fresh supply air using recuperators. Ventilation heat loss can be calculated as:

  5. Displacement ventilation - Wikipedia

    en.wikipedia.org/wiki/Displacement_ventilation

    The research also indicates, that the draft rating model could predict the draft risk with good accuracy in rooms with displacement ventilation systems. There is a tradeoff inherent in these two issues: by increasing the flow rate (and the ability to remove greater thermal loads), the vertical temperature gradient can be reduced, but this could ...

  6. Insulation system - Wikipedia

    en.wikipedia.org/wiki/Insulation_system

    Basic insulation is any material added to protect a user from accidental contact with energized parts. Supplemental insulation is rated to withstand 1500 volts AC. Double insulation is a design concept where failure of one insulation system will not expose the user to a shock hazard due to the presence of a second independent layer of insulation.

  7. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Mechanical ventilation systems may include supply fans (which push outdoor air into a building), exhaust [3] fans (which draw air out of a building and thereby cause equal ventilation flow into a building), or a combination of both (called balanced ventilation if it neither pressurizes nor depressurizes the inside air, [3] or only slightly ...