  1. Results From The WOW.Com Content Network
  2. Current transformer - Wikipedia

    en.wikipedia.org/wiki/Current_transformer

    A high-voltage current transformer may contain several cores, each with a secondary winding, for different purposes (such as metering circuits, control, or protection). [7] A neutral current transformer is used as earth fault protection to measure any fault current flowing through the neutral line from the wye neutral point of a transformer.

  3. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    Shunts are rated by maximum current and voltage drop at that current. For example, a 500 A, 75 mV shunt would have a resistance of 150 microohm, a maximum allowable current of 500 amps and at that current the voltage drop would be 75 millivolts. By convention, most shunts are designed to drop 50 mV, 75 mV or 100 mV when operating at their full ...

  4. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Current transformers used in metering equipment for three-phase 400 ampere electricity supply. A current transformer (CT) is a series connected measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary.

  5. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral of the circuit was not connected to ground. The leakage current was due to the distributed capacitance of the wiring and capacitance of the supply transformer. [4] Such distribution systems were monitored by permanently installed instruments to give an alarm when high leakage current was detected.

  7. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    Current limiting is the practice of imposing a limit on the current that may be delivered to a load to protect the circuit generating or transmitting the current from harmful effects due to a short-circuit or overload. The term "current limiting" is also used to define a type of overcurrent protective device.

  8. Galvanic isolation - Wikipedia

    en.wikipedia.org/wiki/Galvanic_isolation

    Everlight EL817 phototransistor opto-isolator in DIP-4 package Halo TG110-S050N2RL 10/100BASE-TX Ethernet pulse transformer in SO-16 package. Decapped sample on the right. Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted. [1] [2]

  9. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    A smaller type of isolated-phase bus is manufactured for direct-current circuits; this may be used in the field circuit of a generator. Currently, the isolated-phase bus world record current is 52,000 A, for bus manufactured by Alstom Power (since 2015 General Electric Power) and installed at the Civaux Nuclear Power Plant, in 1997.