When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Retardation factor - Wikipedia

    en.wikipedia.org/wiki/Retardation_factor

    An R F value will always be in the range 0 to 1; if the substance moves, it can only move in the direction of the solvent flow, and cannot move faster than the solvent. For example, if particular substance in an unknown mixture travels 2.5 cm and the solvent front travels 5.0 cm, the retardation factor would be 0.50.

  3. R-factor (crystallography) - Wikipedia

    en.wikipedia.org/wiki/R-factor_(crystallography)

    The minimum possible value is zero, indicating perfect agreement between experimental observations and the structure factors predicted from the model. There is no theoretical maximum, but in practice, values are considerably less than one even for poor models, provided the model includes a suitable scale factor.

  4. Response factor - Wikipedia

    en.wikipedia.org/wiki/Response_factor

    The response factor can be expressed on a molar, volume or mass [1] basis. Where the true amount of sample and standard are equal: = where A is the signal (e.g. peak area) and the subscript i indicates the sample and the subscript st indicates the standard. [2]

  5. Chromatographic response function - Wikipedia

    en.wikipedia.org/wiki/Chromatographic_response...

    Chromatographic response function, often abbreviated to CRF, is a coefficient which measures the quality of the separation in the result of a chromatography.. The CRF concept have been created during the development of separation optimization, to compare the quality of many simulated or real chromatographic separations.

  6. Retention distance - Wikipedia

    en.wikipedia.org/wiki/Retention_distance

    In contrast to the similar concept called Retention uniformity, R d is sensitive to R f values close to 0 or 1, or close to themselves. If two values are not separated, it is equal to 0. For example, the R f values (0,0.2,0.2,0.3) (two compounds not separated at 0.2 and one at the start ) result in R D equal to 0, but R U equal to 0.3609.

  7. Specific absorption rate - Wikipedia

    en.wikipedia.org/wiki/Specific_absorption_rate

    Specific absorption rate (SAR) is a measure of the rate at which energy is absorbed per unit mass by a human body when exposed to a radio frequency (RF) electromagnetic field. It is defined as the power absorbed per mass of tissue and has units of watts per kilogram (W/kg).

  8. Receiver operating characteristic - Wikipedia

    en.wikipedia.org/wiki/Receiver_operating...

    A classification model (classifier or diagnosis [7]) is a mapping of instances between certain classes/groups.Because the classifier or diagnosis result can be an arbitrary real value (continuous output), the classifier boundary between classes must be determined by a threshold value (for instance, to determine whether a person has hypertension based on a blood pressure measure).

  9. Range factor - Wikipedia

    en.wikipedia.org/wiki/Range_factor

    Range Factor (commonly abbreviated RF) is a baseball statistic developed by Bill James. It is calculated by dividing putouts and assists by the number of innings or games played at a given defense position . [ 1 ]