This is a list of insulation materials used around the world. Typical R-values are given for various materials and structures as approximations based on the average of available figures and are sorted by lowest value. R-value at 1 m gives R-values normalised to a 1 metre (3 ft 3 in) thickness and sorts by median value of the range.
Installed faced fiberglass batt insulation with its R-value visible (R-21) [1]. The R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive [2] flow of heat, in the context of construction. [3]
is the absolute thermal resistance (K/W) across the thickness of the sample, is the thickness (m) of the sample (measured on a path parallel to the heat flow), is the heat flux through the sample (W·m −2),
The basic unit of insulation coefficient is the R SI, (1 m 2 ⋅K/W). 1 tog = 0.1 R SI. There is also a US clothing unit, the clo , equivalent to 0.155 R SI or 1.55 tog, described in ASTM D-1518. [ 7 ]
This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...
The generalised chemical structure of polyisocyanurate showing the isocyanurate group. The polyols are abbreviated as R-groups.. Polyisocyanurate (/ ˌ p ɒ l ɪ ˌ aɪ s oʊ s aɪ ˈ æ nj ʊər eɪ t /), also referred to as PIR, polyol, or ISO, is a thermoset plastic [1] typically produced as a foam and used as rigid thermal insulation.
EPS is the most common of the foams used and has an R-value (thermal resistance) of about 4 °F·ft 2 ·h/Btu (equivalent to about 0.7 K·m 2 /W) per 25 mm thickness, which would give the 3.5 inches (89 mm) of foam in a 4.5-inch-thick (110 mm) panel an R value of 13.8 (caution: extrapolating R-values over thickness may be imprecise due to non ...
As a result of the high thermal resistance of the gas, spray polyurethane insulation typically has an initial R-value around R-3.4 to R-6.7 per inch. [6] In comparison, glass wool typically has an R-Value of only R-3 to R-4 per inch. [7] Foam insulation blocks all three forms of heat transfer: Conductive heat transfer