A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units. An equivalent ...
A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.
In circuit design, the Y-Δ transform, also written wye-delta and also known by many other names, is a mathematical technique to simplify the analysis of an electrical network. The name derives from the shapes of the circuit diagrams , which look respectively like the letter Y and the Greek capital letter Δ .
A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...
A motor with windings in delta configuration gives low torque at low speed but can give higher top speed. Wye configuration gives high torque at low speed, but not as high top speed. [dubious – discuss] The wye winding is normally more efficient. Delta-connected windings can allow high-frequency parasitic electrical currents to circulate ...
In three phase power circuits, three phase sources and loads can be connected in two different ways, called a "delta" connection and a "wye" connection. In analyzing circuits, sometimes it simplifies the analysis to convert between equivalent wye and delta circuits. This can be done with the wye-delta transform.
Delta unveiled its profit-sharing program in 2007 as the company emerged from bankruptcy, and employees received their first payout in 2008, totaling $158 million.
A wye distribution system is preferred because the transformers present unbalanced loads on the line that cause currents in the neutral wire and are then grounded. However, with a delta distribution system, the unbalanced loads can cause variations in the voltages on the 3-phase wires.