When.com Web Search

  1. Ad

    related to: insulated hose for chilled water unit diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    A chiller used to create chilled water as part of a chilled water system. Chilled water is a commodity often used to cool a building's air and equipment, especially in situations where many individual rooms must be controlled separately, such as a hotel. The chilled water can be supplied by a vendor, such as a public utility, or created at the ...

  3. Chilled beam - Wikipedia

    en.wikipedia.org/wiki/Chilled_beam

    A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.

  4. Insulated pipe - Wikipedia

    en.wikipedia.org/wiki/Insulated_pipe

    Insulated pipes are commonly used for transport of hot water from district heating plants to district heating networks and for distribution of hot water inside district heating networks. Thermal insulation material usually used is polyurethane foam or similar, with a thermal conductivity λ 50 of about 0.024–0.033 W/(m·K

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  6. District cooling - Wikipedia

    en.wikipedia.org/wiki/District_cooling

    In a snow storage frozen water (snow and/or ice) is saved in some kind of storage (pile, pit, cavern etc.). The cold is utilized by pumping melt water to the cooling object, directly in a district cooling system or indirect by a heat exchanger. The lukewarm melt water is then pumped back to the snow where it gets cooled and mixed with new melt ...

  7. Pipe insulation - Wikipedia

    en.wikipedia.org/wiki/Pipe_insulation

    Insulated hot water supply and return hydronic piping on a gas-fired boiler. Since pipework can operate at temperatures far removed from the ambient temperature, and the rate of heat flow from a pipe is related to the temperature differential between the pipe and the surrounding ambient air, heat flow from pipework can be considerable.

  8. Free cooling - Wikipedia

    en.wikipedia.org/wiki/Free_cooling

    The cooling tower water can be directly linked into the flow through the chilled water circuit. If the cooling tower is open then a strainer is required to eliminate any debris that could accumulate within the tower. The cost savings are associated with the limited use of the water chiller energy. There is an increased risk of corrosion using ...

  9. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    Refrigerant based Fan-Coil Unit. Other variants utilize a chilled, or heated water loop for space cooling, or heating, respectively. A fan coil unit (FCU), also known as a Vertical Fan Coil Unit (VFCU), is a device consisting of a heat exchanger (coil) and a fan.