Search results
Results From The WOW.Com Content Network
A procedure for ultrasonic testing is outlined in ASTM C597 - 09. [9]In India, till 2018 ultrasonic testing was conducted according to IS 13311-1992.From 2018, procedure and specification for Ultrasonic pulse velocity test is outlined in IS 516 Part 5:Non destructive testing of concrete Section 1:Ultrasonic Pulse Velocity Testing.
Proceq SA of Switzerland is a technology company in the nondestructive testing space. The company name Proceq is taken from a combination of the words “processes” and “equipment”. The main focus is on imaging solutions for non destructive testing of concrete structures, metal hardness testing, paper roll hardness testing and
Crosshole sonic logging (CSL) is a method to determine the structural integrity of drilled shafts and other concrete piles. The CSL method is considered to be more accurate than sonic echo testing in the determination of structural soundness of concrete within the drilled shaft inside of the rebar cage. This method provides little indication of ...
BS 1881:204 Testing concrete. Recommendations on the use of electromagnetic covermeters; DGZfP:B2: Guideline “für Bewehrungsnachweis und Überdeckungsmessung bei Stahl- und Spannbeton” DIN 1045: Guideline Concrete, reinforced and prestressed concrete structures; ACI Concrete Practices Non Destructive testing 228.2R-2.51: Covermeters
Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.
The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...
The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.
Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties