Search results
Results From The WOW.Com Content Network
In 1967, the ALC 100, the first Waters LC system, was brought to market. According to Leslie S. Ettre in a review about Jim Waters, the LC system was formally introduced at the 1968 Pittsburgh Conference. It was a benchtop system equipped with a Milton Roy pump, syringe injection, and two detectors: a Waters differential refractometer and a UV ...
Chromolith columns, for example, have demonstrated reproducibility of 3,300 sample injections and 50,000 column volumes of mobile phase. Also important to the life cycle of the monolith is its increased mechanical robustness; polymeric monoliths are able to withstand pH ranges from 1 to 14, can endure elevated temperatures, and do not need to ...
Chromatography columns of different types are used in both gas and liquid chromatography: Liquid chromatography: Traditional chromatography columns were made of glass. Modern columns are mostly made of borosilicate glass, acrylic glass or stainless steel. To prevent the stationary phase from leaking out of the column interior a polymer ...
HPLC is distinguished from traditional ("low pressure") liquid chromatography because operational pressures are significantly higher (around 50–1400 bar), while ordinary liquid chromatography typically relies on the force of gravity to pass the mobile phase through the packed column. Due to the small sample amount separated in analytical HPLC ...
A chemist in the 1950s using column chromatography. The Erlenmeyer receptacles are on the floor. Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential absorption of compounds to the adsorbent; compounds move ...
The mobile phase consists of the sample being separated/analyzed and the solvent that moves the sample through the column. In the case of HPLC the mobile phase consists of a non-polar solvent(s) such as hexane in normal phase or a polar solvent such as methanol in reverse phase chromatography and the sample being separated. The mobile phase ...
Hydrophilic interaction chromatography (or hydrophilic interaction liquid chromatography, HILIC) [1] is a variant of normal phase liquid chromatography that partly overlaps with other chromatographic applications such as ion chromatography and reversed phase liquid chromatography.
Reversed-phase liquid chromatography (RP-LC) is a mode of liquid chromatography in which non-polar stationary phase and polar mobile phases are used for the separation of organic compounds. [ 1 ] [ 2 ] [ 3 ] The vast majority of separations and analyses using high-performance liquid chromatography (HPLC) in recent years are done using the ...