When.com Web Search

  1. Ad

    related to: sprinklers not enough pressure to pump 2 gpm liquid co2 bottle system

Search results

  1. Results From The WOW.Com Content Network
  2. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  3. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  4. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  5. Liquid carbon dioxide - Wikipedia

    en.wikipedia.org/wiki/Liquid_carbon_dioxide

    Liquid carbon dioxide is the liquid state of carbon dioxide (CO 2 ), which cannot occur under atmospheric pressure. It can only exist at a pressure above 5.1 atm (5.2 bar; 75 psi), under 31.1 °C (88.0 °F) (temperature of critical point ) and above −56.6 °C (−69.9 °F) (temperature of triple point ). [ 1 ]

  6. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A jockey pump is sized for a flow less than one sprinkler in order to ensure a system pressure drop significant enough to start the main fire pump. Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. The control equipment for jockey pumps may however carry approvals.

  7. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s , e.g. water.

  8. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.

  9. Fire suppression system - Wikipedia

    en.wikipedia.org/wiki/Fire_suppression_system

    An Ansul fire suppression system in a hospital cafeteria Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different ...