When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Power engineering software - Wikipedia

    en.wikipedia.org/wiki/Power_engineering_software

    Power engineering software is a software used to create models, analyze or calculate the design of Power stations, Overhead power lines, Transmission towers, Electrical grids, Grounding and Lightning [clarification needed] systems and others. It is a type of application software used for power engineering problems which are transformed into ...

  3. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Set of three unbalanced phasors, and the necessary symmetrical components that sum up to the resulting plot at the bottom. In 1918 Charles Legeyt Fortescue presented a paper [4] which demonstrated that any set of N unbalanced phasors (that is, any such polyphase signal) could be expressed as the sum of N symmetrical sets of balanced phasors, for values of N that are prime.

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    An unbalanced system is analysed as the superposition of three balanced systems, each with the positive, negative or zero sequence of balanced voltages. When specifying wiring sizes in a three-phase system, we only need to know the magnitude of the phase and neutral currents.

  5. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral carries current if the loads on each phase are not identical. In some jurisdictions, the neutral is allowed to be reduced in size if no unbalanced current flow is expected. If the neutral is smaller than the phase conductors, it can be overloaded if a large unbalanced load occurs.

  6. CPC theory - Wikipedia

    en.wikipedia.org/wiki/CPC_Theory

    The development of CPC-based power theory by Leszek S. Czarnecki was initiated in 1983 when he challenged the correctness of existing power theories as applied to single-phase linear, time-invariant (LTI) loads with nonsinusoidal voltage, and next, he revealed the existence of a scattered current, and invented a method of reactance compensation.

  7. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An asymmetric or unbalanced fault does not affect each of the phases equally. Common types of asymmetric fault, and their causes: line-to-line fault - a short circuit between lines, caused by ionization of air, or when lines come into physical contact, for example due to a broken insulator. In transmission line faults, roughly 5% - 10% are ...

  8. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Standard Scott Connection 3 φ to 2 φ. Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2.

  9. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.