When.com Web Search

  1. Ad

    related to: unbalanced load neutral calculation software
    • Dispatch Software

      Taking the Hassle Out of Keeping

      Accurate Dispatching Records.

    • Pricing

      Plans Start From Only $20/month.

      Start with a Free 30 Day Trial.

    • TMS Tour

      See All the Features of

      TruckingOffice in This Quick Tour.

    • IFTA Reporting Software

      Increase Accuracy of Your IFTA Tax

      Reporting and Save Valuable Time.

Search results

  1. Results From The WOW.Com Content Network
  2. Power engineering software - Wikipedia

    en.wikipedia.org/wiki/Power_engineering_software

    Power engineering software is a software used to create models, analyze or calculate the design of Power stations, Overhead power lines, Transmission towers, Electrical grids, Grounding and Lightning [clarification needed] systems and others. It is a type of application software used for power engineering problems which are transformed into ...

  3. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    Since we have shown that the neutral current is zero we can see that removing the neutral core will have no effect on the circuit, provided the system is balanced. Such connections are generally used only when the load on the three phases is part of the same piece of equipment (for example a three-phase motor), as otherwise switching loads and ...

  4. CPC theory - Wikipedia

    en.wikipedia.org/wiki/CPC_Theory

    The development of CPC-based power theory by Leszek S. Czarnecki was initiated in 1983 when he challenged the correctness of existing power theories as applied to single-phase linear, time-invariant (LTI) loads with nonsinusoidal voltage, and next, he revealed the existence of a scattered current, and invented a method of reactance compensation.

  5. Symmetrical components - Wikipedia

    en.wikipedia.org/wiki/Symmetrical_components

    Set of three unbalanced phasors, and the necessary symmetrical components that sum up to the resulting plot at the bottom. In 1918 Charles Legeyt Fortescue presented a paper [4] which demonstrated that any set of N unbalanced phasors (that is, any such polyphase signal) could be expressed as the sum of N symmetrical sets of balanced phasors, for values of N that are prime.

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral carries current if the loads on each phase are not identical. In some jurisdictions, the neutral is allowed to be reduced in size if no unbalanced current flow is expected. If the neutral is smaller than the phase conductors, it can be overloaded if a large unbalanced load occurs.

  7. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An asymmetric or unbalanced fault does not affect each of the phases equally. Common types of asymmetric fault, and their causes: Common types of asymmetric fault, and their causes: line-to-line fault - a short circuit between lines, caused by ionization of air, or when lines come into physical contact, for example due to a broken insulator .

  8. Load balancing (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Load_balancing_(electrical...

    Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.

  9. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    The other end of the three secondary windings and the neutral are brought down the service drop to the service panel. 230 V loads are connected between any of the three-phase wires and the neutral. Because the phases are 120 degrees from each other, the voltage between any two phases is sqrt(3) * 230V = 400V, compared to the 2 * 120V = 240V in ...

  1. Ad

    related to: unbalanced load neutral calculation software