When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.

  3. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    The pressure at which the control pilot relieves is the functional set pressure of the PORV. When the pilot valve reaches set pressure it opens and releases the pressure from the dome. The piston is then free to open and the main valve exhausts the system fluid. The control pilot opens either to the main valve exhaust pipe or to atmosphere ...

  4. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...

  5. Pigging - Wikipedia

    en.wikipedia.org/wiki/Pigging

    Unlock and open, then close and relock the vent and drain valves. Unlock and open door, load pig into launcher, close and lock door. Unlock and open valves V1 and V3, to create a flow path through the launcher. Partly close ‘kicker’ valve V2 to launch the pig. The launch alarm XA will indicate when the pig has been launched. Open valve V2 ...

  6. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Extreme boiler scale buildup Limescale buildup inside a pipe both reduces liquid flow through the pipe, as well as reduces thermal conduction from the liquid to the outer pipe shell. Both effects will reduce the pipe's overall thermal efficiency when used as a heat exchanger. Boiler feedwater is the water which is supplied to a boiler.

  7. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  8. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  9. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [ 2 ]

  1. Related searches fail open vs close valve in pipe cleaning fluid treatment system video youtube

    shutdown valve failurepilot operated safety valve
    shutdown valve safety