When.com Web Search

  1. Ads

    related to: condenser vs aperture diaphragm

Search results

  1. Results From The WOW.Com Content Network
  2. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    The Arlow-Abbe condenser is a modified Abbe condenser that replaces the iris diaphragm, filter holder, lamp and lamp optics with a small OLED or LCD digital display unit. The display unit allows for digitally synthesised filters for dark-field, Rheinberg, oblique and dynamic (constantly changing) illumination under direct computer control.

  3. Diaphragm (optics) - Wikipedia

    en.wikipedia.org/wiki/Diaphragm_(optics)

    Nine-blade iris Pentacon 2.8/135 lens with 15-blade iris Aperture mechanism of Canon 50mm f/1.8 II lens, with five blades In the human eye, the iris (light brown) acts as the diaphragm and continuously constricts and dilates its aperture (the pupil) A 750nm titanium-sapphire laser beam passing through an iris diaphragm, while opening and closing the iris.

  4. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    The field diaphragm is then partially closed; the edges of the diaphragm should be in the same conjugate image planes as the specimen, therefore should appear in focus. The focus can be adjusted by raising or lowering the condenser lenses and diaphragm. Finally, the field diaphragm is reopened to just beyond the field of view.

  5. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    A bright-field microscope has many important parts including; the condenser, the objective lens, the ocular lens, the diaphragm, and the aperture. Some other pieces of the microscope that are commonly known are the arm, the head, the illuminator, the base, the stage, the adjusters, and the brightness adjuster.

  6. Aperture - Wikipedia

    en.wikipedia.org/wiki/Aperture

    Different apertures of a lens In biology, the pupil (appearing as a black hole) of the eye is its aperture and the iris is its diaphragm. In humans, the pupil can constrict to as small as 2 mm (f / 8.3) and dilate to larger than 8 mm (f / 2.1) in some individuals.

  7. Lenses for SLR and DSLR cameras - Wikipedia

    en.wikipedia.org/wiki/Lenses_for_SLR_and_DSLR...

    Aperture settings are usually not continuously variable; instead, the diaphragm has typically 5–10 discrete settings. The normal "full-stop" f-number scale for modern lenses is as follows: 1, 1.4, 2, 2.8, 4, 5.6, 8, 11, 16, 22, 32, but many lenses also allow setting it to half-stop or third-stop increments.

  8. Optical microscope - Wikipedia

    en.wikipedia.org/wiki/Optical_microscope

    The condenser may also include other features, such as a diaphragm and/or filters, to manage the quality and intensity of the illumination. For illumination techniques like dark field , phase contrast and differential interference contrast microscopy additional optical components must be precisely aligned in the light path.

  9. f-number - Wikipedia

    en.wikipedia.org/wiki/F-number

    The f-number N is given by: = where f is the focal length, and D is the diameter of the entrance pupil (effective aperture).It is customary to write f-numbers preceded by "f /", which forms a mathematical expression of the entrance pupil's diameter in terms of f and N. [1]