A lower rating will apply if multiple conductors are in proximity, since each contributes heat to the others and diminishes the amount of external cooling of the conductors. Depending on the type of insulating material, common maximum allowable temperatures at the surface of the conductor are 60, 75, and 90 °C, often with an ambient air ...
A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature rating. (NEC 310.10) [12] The NEC specifies acceptable numbers of conductors in crowded areas such as inside conduit, referred to as the fill rating.
With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking with ridged, grooves or white stripes on the surface of lamp cord. With transparent cord the hot wire is copper colored, and the neutral is silver colored.
A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.
Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire
The following are nominal current ratings for copper conductors; long runs may require thicker wires to minimize voltage drop. White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits
An example of a copper alloy conductor is cadmium copper wire, which is used for railroad electrification in North America. [5] In Britain the BPO (later Post Office Telecommunications ) used cadmium copper aerial lines with 1% cadmium for extra strength; for local lines 40 lb/mile (1.3 mm dia) and for toll lines 70 lb/mile (1.7 mm dia).
The United States National Electrical Code requires a bare copper, or green or green/yellow insulated protective conductor, a white or grey neutral, with any other colour used for single phase. The NEC also requires the high-leg conductor of a high-leg delta system to have orange insulation, or to be identified by other suitable means such as ...