The magnetic circuit's flux that does not interlink both windings is the leakage flux corresponding to primary leakage inductance L P σ and secondary leakage inductance L S σ. Referring to Fig. 1, these leakage inductances are defined in terms of transformer winding open-circuit inductances and associated coupling coefficient or coupling ...
Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...
[8] [9] The transformer must be operating close to its saturation point, [10] at which a real transformer's leakage inductance decreases dramatically. [11] Following perturbation, the transformer oscillates in and out of the saturated and unsaturated modes of operation each cycle, such that the cycle-average inductance cancels out the power ...
Transformer with gap and leakage flux. Gyrator-capacitor model of a transformer with a gap and leakage flux. The gyrator-capacitor approach can accommodate leakage inductance and air gaps in the magnetic circuit. Gaps and leakage flux have a permeance which can be added to the equivalent circuit as capacitors.
It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.
Thus, for a typical inductance (a coil of conducting wire), the flux linkage is equivalent to magnetic flux, which is the total magnetic field passing through the surface (i.e., normal to that surface) formed by a closed conducting loop coil and is determined by the number of turns in the coil and the magnetic field, i.e.,
Leakage may also mean an unwanted transfer of energy from one circuit to another. For example, magnetic lines of flux will not be entirely confined within the core of a power transformer; another circuit may couple to the transformer and receive some leaked energy at the frequency of the electric mains, which will cause audible hum in an audio application.
Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.