Diffusing capacity of the lung (D L) (also known as transfer factor) measures the transfer of gas from air in the lung, to the red blood cells in lung blood vessels. It is part of a comprehensive series of pulmonary function tests to determine the overall ability of the lung to transport gas into and out of the blood.
Deviation from guidelines can result in false-positive or false negative test results, even though only a small minority of pulmonary function laboratories followed published guidelines for spirometry, lung volumes and diffusing capacity in 2012. [19]
In obstructive lung disease however, the FEV1/FVC is less than 0.7, indicating that FEV1 is significantly reduced when compared to the total expired volume. This indicates that the FVC is also reduced, but not by the same ratio as FEV1. [8] One definition requires a total lung capacity which is 80% or less of the expected value. [9]
Spirometry (meaning the measuring of breath) is the most common of the pulmonary function tests (PFTs). It measures lung function, specifically the amount (volume) and/or speed (flow) of air that can be inhaled and exhaled.
D LCO or T LCO (diffusing capacity or transfer factor of the lung for carbon monoxide (CO), [1]) is the extent to which oxygen passes from the air sacs of the lungs into the blood. Commonly, it refers to the test used to determine this parameter. It was introduced in 1909. [2]
Pulmonary function: increased residual volume, increased total lung capacity, fixed obstruction, low diffusing capacity of the lung for carbon monoxide that corrects with alveolar volume; High-resolution CT scan: diffuse pulmonary nodules 4–10 mm, greater than 20 nodules, mosaic attenuation or air trapping in greater than 50% of the lung
In obstructive lung disease, the FEV1 is reduced due to an obstruction of air escaping from the lungs. Thus, the FEV1/FVC ratio will be reduced. [4] More specifically, according to the National Institute for Clinical Excellence, the diagnosis of COPD is made when the FEV 1 /FVC ratio is less than 0.7 or [8] the FEV 1 is less than 75% of predicted; [9] however, other authoritative bodies have ...
The earliest change in initial pulmonary function testing in various case series was abnormal gas transfer, as assessed by the diffusing capacity for carbon monoxide (DLCO), described in 82% to 97% of patients. [3] [4] [6] It is not unusual for DLCO to be reduced out of proportion to forced expiratory volume in 1 second (FEV1). [99]