When.com Web Search

  1. Ads

    related to: interphase transformer simulink kit manual transmission 2 4

Search results

  1. Results From The WOW.Com Content Network
  2. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Transmission lines are subject to thermal limits (simple megawatt limits on flow), as well as voltage and electrical stability constraints. The simulator must calculate the flows in the AC network that result from any given combination of unit commitment and generator megawatt dispatch, and ensure that AC line flows are within both the thermal ...

  3. Simulink - Wikipedia

    en.wikipedia.org/wiki/Simulink

    Simulink 5.2 7 R14 Simulink 6.0 2004 7.0.1 R14SP1 Simulink 6.1 7.0.4 R14SP2 Simulink 6.2 2005 7.1 R14SP3 Simulink 6.3 7.2 R2006a Simulink 6.4 2006 7.3 R2006b Simulink 6.5 7.4 R2007a Simulink 6.6 2007 7.5 R2007b Simulink 7.0 Last release for Windows 2000 and PowerPC Mac. 7.6 R2008a Simulink 7.1 2008 7.7 R2008b Simulink 7.2 7.8 R2009a Simulink 7. ...

  4. Unified power flow controller - Wikipedia

    en.wikipedia.org/wiki/Unified_Power_Flow_Controller

    A unified power flow controller (UPFC) is an electrical device for providing fast-acting reactive power compensation on high-voltage electricity transmission networks. It uses a pair of three-phase controllable bridges to produce current that is injected into a transmission line using a series transformer. [1]

  5. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Protection coordination is also handled through dividing the power system into protective zones. If a fault were to occur in a given zone, necessary actions will be executed to isolate that zone from the entire system. Zone definitions account for generators, buses, transformers, transmission and distribution lines, and motors. Additionally ...

  6. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Bridge transformers connect 2-wire and 4-wire communication circuits. Being magnetic devices, audio transformers are susceptible to external magnetic fields such as those generated by AC current-carrying conductors. "Hum" is a term commonly used to describe unwanted signals originating from the "mains" power supply (typically 50 or 60 Hz). [20]

  7. Static synchronous compensator - Wikipedia

    en.wikipedia.org/wiki/Static_synchronous_compensator

    A transformer with two secondaries, one Wye-Wye and the other Wye-Delta, can be connected to two separate three-phase, three-level converters to double the number of levels. Additional phase-shifted windings can be used to turn the traditional 6 pulses of a three-level to 12, 24, or even 48 pulses. [ 20 ]

  8. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...

  9. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    Oftentimes, we are only interested in the terminal characteristics of the transmission line, which are the voltage and current at the sending and receiving ends, for performance analysis of the line. The transmission line itself is then modelled as a "black box" and a 2 by 2 transmission matrix is used to model its behaviour, as follows [24] [25]